Detailed explanation of scaffolding sweeping pole specifications

In the field of outdoor building materials construction, the standardized erection of scaffolding sweeping poles is the core link to ensure construction safety. The following is a systematic analysis from three aspects: specification parameters, common hidden dangers, and rectification plans.

First, the specification parameters and technical requirements of scaffolding sweeping poles
1. Height threshold
Fastener/door sweeping pole: ≤200mm from the ground (GB55023-2022); disc-type allows ≤300mm (JGJ231-2010). Actual measurements show that when the traditional scaffolding pole exceeds 200mm, the stability coefficient of the pole decreases by 30%-45%.
2. Logic of vertical and horizontal layout
The vertical sweeping pole is on the top and the horizontal pole is on the bottom (JGJ130-2011). If the horizontal pole is placed on the top, the force of the fastener will be unbalanced.
3. Materials and construction
The tightening torque of the main node fastener is 40-65N·m (sampling rate ≥10%); the base of the vertical pole needs to be equipped with a wooden pad or I-beam base with a width of ≥200mm and a thickness of ≥50mm, and the flatness deviation of the concrete base is ≤3mm. Brickwork support is prohibited.

Second, the fatal hidden danger of over-limit erection of scaffolding sweeping poles
1. Failure of mechanical mechanism
When the sweeping pole exceeds 200mm, a cantilever structure is formed at the bottom of the pole. When the height is 400mm, the slenderness ratio λ reaches the critical value, and the critical load drops to 60% of the theoretical value.
2. Tracing the source of the collapse accident
Case: A construction site in Jiangsu collapsed due to a sweeping pole 500mm high, and the support point of the pole moved up and exceeded the safety limit.

Third, on-site rectification plan and technical compensation for scaffolding sweeping rods
1. Remedial measures
Scheme 1: Reduce the distance between vertical poles to 1.2m×1.2m;
Scheme 2: Add 200mm longitudinal horizontal rods;
Scheme 3: Arrange diagonal braces in a zigzag shape (square steel 100×100×5mm), weld height ≥6mm, and use M20 high-strength parts for bolt connection.
2. Acceptance focus
The foundation needs to be hardened with C20 concrete (thickness ≥150mm), with a bearing capacity of ≥80kPa; the top adjustable bracket screw extends ≤300mm, and the insertion depth is ≥150mm.
The scaffolding sweeping rod specification is a concrete manifestation of mechanical logic. Managers need to implement the “three-check principle”: check height, direction, and node torque to achieve the dual commitment of “quality building materials” and “safe landing”.