Dismantling Procedure and Inspection Flow of Scaffolding

 The Dismantling Procedure of Scaffolding

1) Dismantle the scaffolding per floor from top to bottom.

2) Removing the wall-connecting device per floor. Apply the segmentation demolition. The height difference should not be more than 2 steps. A wall-connecting device should be added if the height difference is more than 2 steps.

3) No throwing to the ground.

 Scaffold Inspection and Acceptance

1) Before foundation completion and scaffold erection.

2) After each set height of 6-8m.

3) Before load-application on the working layer.

4) After level 6 and above the strong wind, level 6 and above heavy rain, freeze-thawing.

5) After reaching the design height.

6) The outage lasted longer than 1 month.

Regular Inspection on Scaffolding

1) Check whether the bar setting and connection, wall-connecting devices, supports, doorway truss meet the requirements.

2) Check whether the foundation is waterlogged, whether the base looses, whether the pole is suspended, whether the fastener bolt looses.

3) Whether the safety protection measure is in place.

4) Whether the scaffolding is overloaded.


Post time: May-04-2021


We use cookies to offer a better browsing experience, analyze site traffic, and personalize content. By using this site, you agree to our use of cookies.